@Scoeerg Scoeerg commented Oct 27, 2025

Function bmi08a_get_meas_conf() reads

/*!

  • @brief This API reads the accel config value i.e. odr, band width and range from the sensor,
  • store it in the bmi08_dev structure instance passed by the user.

*/
int8_t bmi08a_get_meas_conf(struct bmi08_dev *dev)

while bmi08a_set_meas_conf() only does ODR and bandwidth.

/*!

  • @brief This API sets the output data rate and bandwidth
  • of accel sensor.
    */
    int8_t bmi08a_set_meas_conf(struct bmi08_dev *dev)

To fix this, I added acceleration range setting to bmi08a_set_meas_conf(). To not break other code, one might alternatively consider a new function

/*!
 * @brief This API sets the acceleration range
 * of accel sensor.
 */
int8_t bmi08a_set_range_conf(struct bmi08_dev *dev){

int8_t rslt;
uint8_t range;
is_range_invalid = FALSE;
rslt = dev_null_ptr_check(dev);
/* Proceed if null check is fine */
    if (rslt == BMI08_OK)
    {
       range = dev->accel_cfg.range;
       if(range > BMI088_ACCEL_RANGE_24G)
       {
            /* Updating the status */
            is_range_invalid = TRUE;
        }
       if (!is_range_invalid)
       {
          rslt = bmi08a_get_set_regs(BMI08_REG_ACCEL_RANGE, &range, BMI08_REG_ACCEL_RANGE_LENGTH, dev, SET_FUNC);
          if (rslt == BMI08_OK)
          {
             /* Delay required to set accel configurations */
             dev->delay_us(BMI08_SET_ACCEL_CONF_DELAY * 1000, dev->intf_ptr_accel);
          }
       }
       else
       {
           /* Invalid configuration present in RANGE */
           rslt = BMI08_E_INVALID_CONFIG;
       }
   }
return rslt;
}

@Scoeerg
Copy link
Author

Scoeerg commented Nov 6, 2025

https://community.bosch-sensortec.com/mems-sensors-forum-jrmujtaw/post/pull-request-to-fix-asymmetric-bmi08a-get-meas-conf-and-bmi08a-set-meas-YeDesIrYKsA8OHg

tl;dr

Hi EricSchoeneberg,

I think your idea is great, but BST github isn't open source. Therefore, unfortunately, we don't allow users to do pull request. Maybe next release will fix the issue.

Thanks

I will leave the merge-request open for others to find the fix who might encounter similar issues.