Data display application for Weather Station The weather station controller implements a Modbus RTU Slave protocol over RS485 port. The config parameters for the port are available on the CLI port.

Modbus object types

All modbus RTU object type with standard addresses are implemented : Coils, Discrete Inputs, Input registers, Holding registers.

Coils

Acces level Read/Write, Size 1 bit

Device function Modbus Address Description
COIL_START_CALIB_CMD 0x01 Write 1 to start calibration with the last values from the calibration registers
COIL_COUNT_RST 0x02 Write 1 to reset the pulse counter

Discrete Inputs

Access level Read Only, Size 1 bit

Device function Register Address Modbus Address Description
DI_CALIB_PROGRESS 0x01 10001 Calibration in progress flag
DI_CALIB_DONE 0x01 10002 Calibration done flag
DI_CALIB_ERROR 0x01 10003 Calibration error flag
DI_EXT_SNS_ERROR 0x01 10004 External pressure sensor (BME280) error flag
DI_INT_SNS_ERROR 0x01 10005 Internal pressure sensor error flag
DI_ACC_ERROR 0x01 10006 Acceleration sensor error flag

Input registers

Access level Read Only, Size 16 bits

Device function Register Address Description Measurement Unit
IR_4_20MA_IN_HI1 30001 4-20mA Input 1 high word of float
IR_4_20MA_IN_LO1 30002 4-20mA Input 1 low word of float
IR_4_20MA_IN_HI2 30003 4-20mA Input 2 high word of float
IR_4_20MA_IN_LO2 30004 4-20mA Input 2 low word of float
IR_0_5V_IN_HI 30005 0-5V Input high word
IR_0_5V_IN_LO 30006 0-5V Input low word
IR_RTD_HI 30007 Temperature of PT1000 RTD sensor high word °C
IR_RTD_HI 30008 Temperature of PT1000 RTD sensor low word °C
IR_PULSE_COUNTER 30009 Counter for digital inpiut
IR_PHOTO_HI 30010 Photo sensor high word
IR_PHOTO_LO 30011 Photo sensor low word
IR_INT_PRESS_HI 30012 Internal pressure sensor high word of float Pa
IR_INT_PRESS_LO 30013 Internal pressure sensor low word of float Pa
IR_INT_TEMP_HI 30014 Internal temperature sensor high word °C
IR_INT_TEMP_LO 30015 Internal temperature sensor low word °C
IR_PITCH_HI 30016 Inclination angle, pitch high word °
IR_PITCH_LO 30017 Inclination angle, pitch low word °
IR_ROLL_HI 30018 Inclination angle, roll high word °
IR_ROLL_LO 30019 Inclination angle, roll low word °
IR_EXT_PRESS_HI 30020 Ext BME280 pressure high word of float Pa
IR_EXT_PRESS_LO 30021 Ext BME280 pressure low word of float Pa
IR_EXT_TEMP_HI 30022 Ext BME280 temperature high word °C
IR_EXT_TEMP_LO 30023 Ext BME280 temperature low word °C
IR_EXT_HUM_HI 30024 Ext BME280 humidity high word %
IR_EXT_HUM_LO 30025 Ext BME280 humidity low word %
IR_PULSE_H 30026 Pulses per hour for rain sensor
IR_PULSE_24H 30027 Pulses per day for rain sensor
IR_0_100MV_IN_HI 30028 0-100mV Input high word
IR_0_100MV_IN_LO 30029 0-100mV Input low word
IR_FW_VERSION 30030 Firmware version

Holding registers

Access level Read/Write, Size 16 bits

Device function Register Address Modbus Address Measurement Unit Range Comment
HR_CALIB_VALUE_HI 40001 0x00 Calibration value as a floating point number
HR_CALIB_VALUE_LO 40002 0x01 Calibration value as a floating point number
HR_CALIB_CH 40003 0x02 Calibration works only from command line
HR_BAUDRATE 40004 0x03 hz/100 12..9216
HR_ADDRESS 40005 0x04 1..254
HR_PARITY 40006 0x05 0..2 0=NONE; 1=EVEN; 2=ODD
HR_PARAM_RTD_SLOPE_HI 40007 0x06 RTD slope high word
HR_PARAM_RTD_SLOPE_LO 40008 0x07 RTD slope low word
HR_PARAM_RTD_INTERCEPT_HI 40009 0x08 RTD intercept high word
HR_PARAM_RTD_INTERCEPT_LO 40010 0x09 RTD intercept low word
HR_PARAM_VIN_SLOPE_HI 40011 0x0A Voltage input slope high word
HR_PARAM_VIN_SLOPE_LO 40012 0x0B Voltage input slope low word
HR_PARAM_VIN_INTERCEPT_HI 40013 0x0C Voltage input intercept high word
HR_PARAM_VIN_INTERCEPT_LO 40014 0x0D Voltage input intercept low word
HR_PARAM_CRT1_SLOPE_HI 40015 0x0E Current 1 slope high word
HR_PARAM_CRT1_SLOPE_LO 40016 0x0F Current 1 slope low word
HR_PARAM_CRT1_INTERCEPT_HI 40017 0x10 Current 1 intercept high word
HR_PARAM_CRT1_INTERCEPT_LO 40018 0x11 Current 1 intercept low word
HR_PARAM_CRT2_SLOPE_HI 40019 0x12 Current 2 slope high word
HR_PARAM_CRT2_SLOPE_LO 40020 0x13 Current 2 slope low word
HR_PARAM_CRT2_INTERCEPT_HI 40021 0x14 Current 2 intercept high word
HR_PARAM_CRT2_INTERCEPT_LO 40022 0x15 Current 2 intercept low word
HR_PARAM_PHOTO_SLOPE_HI 40023 0x16 Photo sensor slope high word
HR_PARAM_PHOTO_SLOPE_LO 40024 0x17 Photo sensor slope low word
HR_PARAM_PHOTO_INTERCEPT_HI 40025 0x18 Photo sensor intercept high word
HR_PARAM_PHOTO_INTERCEPT_LO 40026 0x19 Photo sensor intercept low word
HR_PARAM_BARO_SLOPE_HI 40027 0x1A Barometric pressure slope high word
HR_PARAM_BARO_SLOPE_LO 40028 0x1B Barometric pressure slope low word
HR_PARAM_BARO_INTERCEPT_HI 40029 0x1C Barometric pressure intercept high word
HR_PARAM_BARO_INTERCEPT_LO 40030 0x1D Barometric pressure intercept low word
HR_PARAM_ACC_X_1G_HI 40031 0x1E Accelerometer X 1G calibration high word
HR_PARAM_ACC_X_1G_LO 40032 0x1F Accelerometer X 1G calibration low word
HR_PARAM_ACC_X_OFFSET_HI 40033 0x20 Accelerometer X offset high word
HR_PARAM_ACC_X_OFFSET_LO 40034 0x21 Accelerometer X offset low word
HR_PARAM_ACC_Y_1G_HI 40035 0x22 Accelerometer Y 1G calibration high word
HR_PARAM_ACC_Y_1G_LO 40036 0x23 Accelerometer Y 1G calibration low word
HR_PARAM_ACC_Y_OFFSET_HI 40037 0x24 Accelerometer Y offset high word
HR_PARAM_ACC_Y_OFFSET_LO 40038 0x25 Accelerometer Y offset low word
HR_PARAM_ACC_Z_1G_HI 40039 0x26 Accelerometer Z 1G calibration high word
HR_PARAM_ACC_Z_1G_LO 40040 0x27 Accelerometer Z 1G calibration low word
HR_PARAM_ACC_Z_OFFSET_HI 40041 0x28 Accelerometer Z offset high word
HR_PARAM_ACC_Z_OFFSET_LO 40042 0x29 Accelerometer Z offset low word
HR_PARAM_PITCH_OFFSET_HI 40043 0x2A Pitch angle offset high word
HR_PARAM_PITCH_OFFSET_LO 40044 0x2B Pitch angle offset low word
HR_PARAM_ROLL_OFFSET_HI 40045 0x2C Roll angle offset high word
HR_PARAM_ROLL_OFFSET_LO 40046 0x2D Roll angle offset low word
HR_PARAM_MODBUS_BAUDRATE_HI 40047 0x2E Modbus baudrate configuration high word
HR_PARAM_MODBUS_BAUDRATE_LO 40048 0x2F Modbus baudrate configuration low word
HR_PARAM_MODBUS_SETTINGS_HI 40049 0x30 Modbus settings high word
HR_PARAM_MODBUS_SETTINGS_LO 40050 0x31 Modbus settings low word
HR_PARAM_VIN_RANGE_HI 40051 0x32 Voltage input range high word
HR_PARAM_VIN_RANGE_LO 40052 0x33 Voltage input range low word
HR_PARAM_MVIN_SLOPE_HI 40053 0x34 Millivolt input slope high word
HR_PARAM_MVIN_SLOPE_LO 40054 0x35 Millivolt input slope low word
HR_PARAM_MVIN_INTERCEPT_HI 40055 0x36 Millivolt input intercept high word
HR_PARAM_MVIN_INTERCEPT_LO 40056 0x37 Millivolt input intercept low word
HR_PARAM_RTD_LOW_LIMIT_HI 40057 0x38 RTD low limit high word
HR_PARAM_RTD_LOW_LIMIT_LO 40058 0x39 RTD low limit low word
HR_PARAM_RTD_HIGH_LIMIT_HI 40059 0x3A RTD high limit high word
HR_PARAM_RTD_HIGH_LIMIT_LO 40060 0x3B RTD high limit low word
HR_PARAM_VIN_LOW_LIMIT_HI 40061 0x3C Voltage input low limit high word
HR_PARAM_VIN_LOW_LIMIT_LO 40062 0x3D Voltage input low limit low word
HR_PARAM_VIN_HIGH_LIMIT_HI 40063 0x3E Voltage input high limit high word
HR_PARAM_VIN_HIGH_LIMIT_LO 40064 0x3F Voltage input high limit low word
HR_PARAM_CRT1_LOW_LIMIT_HI 40065 0x40 Current 1 low limit high word
HR_PARAM_CRT1_LOW_LIMIT_LO 40066 0x41 Current 1 low limit low word
HR_PARAM_CRT1_HIGH_LIMIT_HI 40067 0x42 Current 1 high limit high word
HR_PARAM_CRT1_HIGH_LIMIT_LO 40068 0x43 Current 1 high limit low word
HR_PARAM_CRT2_LOW_LIMIT_HI 40069 0x44 Current 2 low limit high word
HR_PARAM_CRT2_LOW_LIMIT_LO 40070 0x45 Current 2 low limit low word
HR_PARAM_CRT2_HIGH_LIMIT_HI 40071 0x46 Current 2 high limit high word
HR_PARAM_CRT2_HIGH_LIMIT_LO 40072 0x47 Current 2 high limit low word
HR_PARAM_PHOTO_LOW_LIMIT_HI 40073 0x48 Photo sensor low limit high word
HR_PARAM_PHOTO_LOW_LIMIT_LO 40074 0x49 Photo sensor low limit low word
HR_PARAM_PHOTO_HIGH_LIMIT_HI 40075 0x4A Photo sensor high limit high word
HR_PARAM_PHOTO_HIGH_LIMIT_LO 40076 0x4B Photo sensor high limit low word
HR_PARAM_BARO_LOW_LIMIT_HI 40077 0x4C Barometric pressure low limit high word
HR_PARAM_BARO_LOW_LIMIT_LO 40078 0x4D Barometric pressure low limit low word
HR_PARAM_BARO_HIGH_LIMIT_HI 40079 0x4E Barometric pressure high limit high word
HR_PARAM_BARO_HIGH_LIMIT_LO 40080 0x4F Barometric pressure high limit low word
HR_PARAM_MVIN_LOW_LIMIT_HI 40081 0x50 Millivolt input low limit high word
HR_PARAM_MVIN_LOW_LIMIT_LO 40082 0x51 Millivolt input low limit low word
HR_PARAM_MVIN_HIGH_LIMIT_HI 40083 0x52 Millivolt input high limit high word
HR_PARAM_MVIN_HIGH_LIMIT_LO 40084 0x53 Millivolt input high limit low word
HR_SPARE 40085 0x54 Spare register

Function codes implemented

  • Read Coils (0x01)
  • Read Discrete Inputs (0x02)
  • Read Holding Registers (0x03)
  • Read Input Registers (0x04)
  • Write Single Coil (0x05)
  • Write Single Register (0x06)
  • Write Multiple Coils (0x0f)
  • Write Multiple registers (0x10)

Notes: The calibration can be done and monitored only from CLI, so the variables calibration related are not implemented