The Machine Access Interlock Controller is an industrial safety device intended to be used in conjunction with the site access control system to ensure a machine can only be enabled (powered) when all safety interlocks are engaged (“sealed”), and the user is authorised. It disables the machine if any interlock is broken or a fault is detected. Upon enabling the machine, timers ensure the machine does not remain enabled once the user has finished. Machine run-time is detected via current transformer input, with configurable threshold, calibration, and amps-per-volt ratio. Designed for reliability and configurability, with persistent configuration stored in flash memory, and provides a serial terminal menu for setup and diagnostics.
- Multiple Interlock Inputs: Four independent interlock channels, each can be enabled/disabled in software.
- Safety Relays: Controls contactors and output gates to enable/disable machine power.
- Current Sensing: Monitors machine current via CT (current transformer) input, with configurable threshold, calibration, and amps-per-volt ratio.
- Timers: Configurable enable (pre-start) and pause (post-stop) timers.
- Fault Detection: Detects faults such as power supply undervoltage/overvoltage, CT disconnect, overcurrent, and running while disabled.
- Status Indication: RGB LEDs for status, enable, and interlock indication.
- Persistent Configuration: All settings are stored in flash memory and survive power cycles.
- Serial Terminal Menu: Interactive configuration and status via serial terminal (115200 baud), with ANSI color support.
- Inputs:
- 4× Interlock inputs (dry contact, pulled up)
- 1× Enable input (dry contact, pulled up)
- 1× CT analog input (current transformer)
- 1× PSU voltage feedback
- Outputs:
- Contactor 24VDC coil control
- Machine status (running/idle)
- Fault/alarm status
- Status RGB LED
- Enable and interlock LEDs
- Board: Custom board definition (
scion_isc_m0.json), with pin mappings insrc/sys_init.h.
- On power-up, the device loads configuration from flash. If not initialised, it writes defaults.
- The main loop continuously checks interlock status, current draw, and handles timers.
- If all interlocks are sealed and enable input is active, the machine can be enabled.
- If any interlock opens or a fault occurs, the machine is immediately disabled.
- Configuration (interlocks, timers, current settings) is accessible via the serial terminal menu.
- All changes can be saved to flash for persistence.
- Uses a
flash_datastruct to store:- Interlock enable/disable states
- Enable & pause timer values
- Current threshold
- CT calibration multiplier
- Amps-per-volt ratio
- Data is validated on load; defaults are restored if out-of-range.
- Connect at 115200 baud.
- Menu allows:
- Enable/disable interlock inputs
- Setting enable/pause timers
- Adjusting current threshold
- Setting CT ratio and calibration
- Changes can be saved to flash by typing
's'in the menu.
- Power supply undervoltage/overvoltage
- CT disconnected
- Overcurrent
- Running while disabled (tamper detection)
- Platform: Arduino (via PlatformIO)
- Board:
scion_isc_m0(custom board) - Build:
- Install PlatformIO
- Build and upload using PlatformIO, or use Arduino IDE with proper board support
- Configuration: See
platformio.inifor environment and dependencies
src/– Main source codehardware/– Schematics, PCB, and pinout documentationboards/– Custom board definitionlib/– Libraries (including FlashStorage for persistent config)platformio.ini– PlatformIO build configuration
(C) 2024 Scion Research. For internal and research use. See source files for details.