Skip to content

Revise emis coeffs in light of troubled JEDI#465

Open
rtodling wants to merge 3 commits intodevelopfrom
bugfix/rtodling/temporary_fix_for_ir_sfc_emiss
Open

Revise emis coeffs in light of troubled JEDI#465
rtodling wants to merge 3 commits intodevelopfrom
bugfix/rtodling/temporary_fix_for_ir_sfc_emiss

Conversation

@rtodling
Copy link
Contributor

Description

After considerable looking I find that a temporary solution to the issue associated with the very large increments of T-skin obtained from IR instruments in JEDI can be alleviated by rescaling the emissivity coeffs in the surface Jacobian filter as indicated here.

I have long discussions in the SWELL issue:

and also - even more extensive here: https://github.com/orgs/JCSDA-internal/discussions/156

The palliative being put forward here meant to allow GMAO to run with a JEDI configuration with known issues minimized as much as possible.

It is still necessary to look more carefully at this and figure try to figure out why JEDI gets such large IR emissivities to begin with.

Dependencies

None

Impact

Much more reasonable results.

@rtodling rtodling linked an issue Dec 11, 2024 that may be closed by this pull request
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

Something is amiss in IR radiance assimilation