Notifications
You must be signed in to change notification settings - Fork 29
Open
Description
Description
Error message to be more appropriate when deleting a DA without deleting the SFC
Expected Behavior
Error message should be more suggestive - e.g. DA cannot be deleted unless the SFC is deleted
Actual Behavior
Error message when deleting DA when SFC is not deleted - Distributed Appliance is currently protecting a workload
Steps to Reproduce
- Create a VC (using SDN - Neutron-sfc), MC, DA, DS, SG.
- Create SFC.
- Bind the SG to SFC.
- Now delete the SG.
- Delete DA
- Get an error message - Distributed Appliance is currently protecting a workload
This suggests that probably there is a SG being protected, whereas, in reality we need to delete the SFC to delete the DA.
Additional Information
WORKAROUND - delete the SFC and then DA delete will be successful
Environment
- OSC Version/Build: Version: 1.0.0-SNAPSHOT (Build:112-g42e1905, 2017-10-11T18:46:02Z)
- Cloud Provider Info:
- Plugin Info:
- Other:
Status
- Reproduced
- In Progress
- Validated => Verified in Version/Build: