Notifications
You must be signed in to change notification settings - Fork 7
Description
Take the following curb inlet:
| Property | Value |
|---|---|
| Long Slope | 1% |
| Sx | 2% |
| Sw | 0.0 |
| Curb Length | 3 ft |
| Local Depression Width | 2 ft |
| Local Depression Height | 2 inches |
| Flow | 1 Cfs |
SWMM calculates a capture efficiency of around 60%, but if you run the same inlet in the FHWA Hydraulic Toolbox, you get a capture efficiency of around 48%
SWMM is calculating the upstream spread taking into account the local depression, whereas the spread computation should ignore the local depression, and be based on the incoming uniform gutter.
Here is a quote from HEC-22
Remember that for locally depressed inlets, the quantity of flow reaching the inlet would be dependent on the upstream gutter section geometry and not the depressed section geometry. (HEC-22, 4-41)
UI Issue
There is another related UI issue that I will bring up here as well, the local depression width and local depression height on the street view get messed up on save and reopen of the SWMM project and u need to re-enter them.